• 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
  • 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
  • 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
  • 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
  • 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
  • 900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller

After-sales Service: with
Warranty: 1 Year
Output Type: AC Three Phase
Samples:
US$ 268/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller pictures & photos
900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
US $58-362 / Piece
Min. Order: 5 Pieces
Diamond Member Since 2007

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Company Introduction
  • New Upgrade
  • Style Selection
  • Product Display
  • Hot Sale
  • Technical Parameter
  • Frequently Asked Questions
Overview

Basic Info.

Model NO.
Gasoline Generator
Starting
Electric Start
Phase
Three-Phase
Power
5-10kW
Standard
Standard
Rated Power
900W 2000W 2800W 4000W 5000W 6000W 7000W 8000W
Maximum Power
1000W 2200W 300W 4500W 5500W 6500W 7500W 8500W
Rated kVA
2.5kVA 3.5kVA 5kVA 6.25kVA 7.5kVA 8.75kVA 10kVA
Maximum kVA
1.25kVA 2.75kVA 3.75kVA 5kVA 6.875kVA 8.125kVA 8
Engine
168f 170f 177f 188f 190f 192f
Rated Voltage
220V/380V
Frequency
50Hz/60Hz
Starting Mode
Electric/Manual
Oil Capacity
0.6L 1.1L
Fuel Tank
15L 25L
Motor Coil
Copper Wire Aluminium Wire
Displacement
163cc 186cc 208cc 270cc 337cc 389cc 420cc 678cc
Ignition System
Non-Contact Transistor
Product Model
2500 3000 3500 4500 5500 6500 7500 8500
Engine Type
Single Cylineder, 4-Stroke, Air-Cooled
Transport Package
Carton or Wooden Case
Specification
69.5*52.5*55.5
Trademark
ELEM
Origin
Made in China
HS Code
8502200000
Production Capacity
25413

Product Description

Company Introduction

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
New Upgrade

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
Style Selection

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
Product Display

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
1. Open the dipstick and add four-stroke oil. Ensure you use the recommended oil type for optimal performance.
2. Add oil between L and H. This is crucial for maintaining the engine's health and longevity.
3. Open the petrol cap and add No. 92 petrol. Ensure the cap is securely fastened afterward.
4. Observe the gasoline capacity through the fuel gauge. Make sure there is enough fuel for the operation.
5. Press down to open the oil switch. This will allow the oil to flow freely throughout the engine.
6. Move the lever to the left to close the damper. This helps in starting the engine with ease.
7. Open the kill switch. This switch needs to be in the 'on' position for the generator to start.
8. Open the breaker. This ensures that the generator can deliver power to the connected appliances.
9. Pull the handle of the disc. Start with a short pull, then a long and fast pull. This will help in igniting the engine efficiently.
10. Press the damper to the right after startup. This will ensure optimal engine operation.

900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller

Hot Sale

Hot Sale
900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller
900W to 8500W Maximum Power Single Phase Diesel Gasoline Generator with Controller

Technical Parameter

Technical parameter

Rated power 900W 2000W 2500W 2800W 5000W 6000W 7000W 8000W
Maximum power 1000W 2200W 2700W 3000W 5500W 6500W 7500W 8500W
Dimension 48*37*39 61*44*45 61*44*45 61*44*45 72*54*60 72*54*60 72*54*60 72*54*60
Engine 156F 168F-1 170F 170F 188F 190F 192F 192F
Continuous operation 6H 13H 14H 12H 9H 8H 8H 8H
weight 28KG 36KG 44KG 50KG 82KG 83KG 87KG 90KG

Type stroke Single cylinder/four stroke/forced air cooled gasoline engine

Voltage 220V 110V/220V/380V
Frequency 50Hz 50Hz/60Hz
Starting mode Manual Electric/Manual

Fuel tank 6L 15L 25L

Oil capacity 0.6L 1.1L



Matters needing attention
1. Pay attention to style, fuel tank color, tray color, and frame color when ordering. Customization options are available to match your preferences.
2. Optionally equipped with wheels and handles. This feature enhances mobility and convenience.
3. For orders less than 50 sets, full payment is required upfront. For orders exceeding 50 sets, a 30% deposit is needed before delivery, with the remaining 70% due upon completion.
4. The default packaging is in cartons. For larger quantities, customized wooden cases can be arranged for better protection.
Frequently Asked Questions

FAQ
1. Does the gasoline generator use fuel? Yes, it uses gasoline as the primary fuel source. This type of fuel is economically viable and can sustain long-term use with minimal consumption.
Most quiet (smaller and inverter) generators use gasoline as the fuel source. They are economically viable and can provide basic needs for a long time on a minimum amount of fuel.
2. What is the function of a gasoline generator? It serves as either a prime or standby power source for your property. Compared to diesel generators, gasoline models have an edge as their fuel lines run underground, reducing the risk of external interference, and gasoline does not degrade over time as diesel does.
A gas generator can also be used to function as either a prime or standby generator for a property and is arguably better than a diesel generator as the gas lines would be located underground, away from any outside interference, and the gas feeding the generator doesn't deteriorate over time like diesel would.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now