1. Begin by opening the dipstick and adding the required four-stroke oil to the engine.
2. Ensure that the oil level is between the L (Low) and H (High) marks on the dipstick.
3. Open the petrol cap and fill the tank with No. 92 petrol, ensuring an adequate amount for operation.
4. Monitor the gasoline level through the fuel gauge to avoid overfilling or shortages.
5. Press down the lever to open the oil switch, allowing the oil to flow into the system.
6. Move the lever to the left to close the damper, managing the air-fuel mixture appropriately.
7. Activate the kill switch to ensure safety during operation.
8. Flip open the circuit breaker to initiate the electrical flow.
9. Grasp the pull handle, giving it a short pull followed by a long, swift pull to start the engine.
10. Once the engine is running, press the damper to the right to stabilize the engine's performance.
Hot Sale
Rated power |
900W |
2000W |
2500W |
2800W |
5000W |
6000W |
7000W |
8000W |
Maximum power |
1000W |
2200W |
2700W |
3000W |
5500W |
6500W |
7500W |
8500W |
Dimension |
48*37*39 |
61*44*45 |
61*44*45 |
61*44*45 |
72*54*60 |
72*54*60 |
72*54*60 |
72*54*60 |
Engine |
156F |
168F-1 |
170F |
170F |
188F |
190F |
192F |
192F |
Continuous operation |
6H |
13H |
14H |
12H |
9H |
8H |
8H |
8H |
weight |
28KG |
36KG |
44KG |
50KG |
82KG |
83KG |
87KG |
90KG |
Type stroke |
Single cylinder/four stroke/forced air cooled gasoline engine |
Voltage |
220V |
110V/220V/380V |
Frequency |
50Hz |
50Hz/60Hz |
Starting mode |
Manual |
Electric/Manual |
Matters needing attention
1. Pay attention to the style, fuel tank color, tray color, and frame color when placing an order.
2. Optional equipment includes wheels and handles for enhanced mobility.
3. For orders under 50 sets, full payment is required upfront. For orders over 50 sets, a 30% deposit is required with the remaining 70% due before delivery.
4. Standard delivery is in carton packaging; for large orders, customized wooden cases are available.
Frequently Asked Questions
FAQ
1. Does the gasoline generator use fuel?
Yes, most compact and inverter generators use gasoline as their fuel source. They are cost-effective and can meet basic energy needs for extended periods with minimal fuel consumption.
2. What is the function of a gasoline generator?
A gasoline generator can serve as both a primary and backup power source for properties. It is often preferred over diesel generators because the gas lines are securely buried underground, reducing the risk of external interference. Additionally, gasoline does not degrade over time like diesel, ensuring a reliable energy supply.